Publications

Fremtiden er trebasert
Publication Year: 2014



Freeze protection in ventilation systems is important to avoid freeze damages and increase in maintenance costs. Freezing in a ventilation system can appear in construction and operation phase. The aim of this study was to test a new method for freeze protection in ventilation system. This method implies use of an additional heat exchanger. The method used two hydronic circuits: the first one with water on energy supply side, and second one with mixture of glycol and water at the secondary side. The mixture transfers heat from the energy source via an additional heat exchanger to the coil in the…

Framtidas isolasjon
Publication Year: 2013


Framing Transitions
Authors: Publication Year: 2013


The role of tunnel K+ ions on the growth and stability of tunnel-structured cryptomelane-type MnO2 nanofibers (denoted as cryptomelane nanofibers hereafter) has been discussed by means of X-ray diffraction and electron microscopy. Cryptomelane nanofibers with typical diameters of 20–80 nm and lengths of 1–6 μm have been synthesized by means of a simple hydrothermal reaction of KMnO4 and MnSO4 aqueous solutions at 140 °C. The growth of cryptomelane nanofibers under hydrothermal conditions follows a dissolution–recrystallization process and involves a morphological transformation from a layered precursor to the tunnel-structured cryptomelane, in which the K+ ions play important roles in templating and…

Et ordinært kontorbygg fra 80-tallet skal skape mer energi enn det bruker.    

Forskningssenteret ZEB
Authors: Publication Year: 2009


Forskningsprogrammet ZEB
Authors: Publication Year: 2010



Drawing on theories from studies of Facilities Management (FM) and social studies of science and technology as well as explorative qualitative research methods the purpose of this paper is to examine energy operations of large, existing buildings and how knowledge development and knowledge transfers may provide lessons for how FM of existing buildings may contribute to transition towards zero emission buildings. In this energy operation of existing buildings is described as an important measure towards sustainability. The relevant actors explored for this study are related to large non-residential buildings (university), and different types of large housing facilities (health rehabilitation and…

Ådland får verdens mest miljøvennlige boliger, mener Arbeiderpartiets Ruth Grung. Tirsdag ga miljøvernministeren grønt lys for nullutslippboligene på Ådland.   Skrevet at Terje Bringsvor Nilsen

ABSTRACT The path toward energy-efficient buildings with a low or zero carbon footprint, e.g. zero energy and zero emission buildings, involves the development of high-performance thermal insulation, aiming at reaching thermal conductivities far below 20 mW/(mK). Applying such superinsulation will allow the construction of relatively thin building envelopes yet maintaining a high thermal resistance, thus also increasing the architectural design possibilities. A vacuum insulation panel (VIP) represents a stateof-the-art thermal insulation solution with a thermal conductivity of typical 4 mW/(mK) in the pristine and non-aged condition. However, the VIPs have issues with fragility, perforation vulnerability, increasing thermal conductivity during time…

Abstract Improvements to concrete will have a large impact in the construction and building sector. As the attention is drawn towards energy-efficient and zero emission buildings, the thermal properties of concrete will be important. Attempts are being made to decrease the thermal conductivity of concrete composites while retaining as much as possible of the mechanical strength. In this study experimental investigations of aerogel-incorporated mortar (AIM) with up to 80 vol% aerogel are prepared utilizing a reduced ultra-high performance concrete (UHPC) recipe. It was found that at 50 vol% aerogel content, the AIM sample possessed a compressive strength of 20 MPa and a thermal…

While window frames typically represent 20%"30% of the overall window area, their impact on the total window heat transfer  rates may be much larger. This effect is even greater in low-conductance (highly insulating) windows that incorporate very low  conductance glazings. Developing low-conductance window frames requires accurate simulation tools for product research and  development.  The Passivhaus Institute in Germany states that windows (glazing and frames, combined) should have U-factors not exceeding  0.80 W/(m² K). This has created a niche market for highly insulating frames, with frame U-factors typically around 0.7-1.0 W/  (m² K). The U-factors reported are often based on numerical…

Responsive Building Elements (RBEs) and energy storage within the building are considered as a crucial development towards the nearly Zero Energy/Emission Building target. The exploitation at the building scale of renewable energy sources and the opportunities offered by the environment is achieved by the ability of the RBEs to dynamically adapt to changing environmental conditions. Among these concepts, Advanced Integrated Façades (AIFs) are probably one the most promising technologies, due to the important role that the building envelope plays in controlling the energy and mass flows between the building and the outdoor environment. In the framework of a decade-long research…